AGM BATTERY BAT 5AH-18AH is the general purpose battery with 5 years design life for float service. It meets IEC and JIS standards. With up-dated AGM valve regulated technology and high purity raw materials, the RT series battery has reliable standby service life.
It is suitable for UPS/EPS, medical equipment, emergency light and security systems applications.
Characteristics
Capacity range : 1.3Ah – 28Ah
Voltage class : 6V/12V
Long design life (25C) : 5 years
Low self-discharge rate : < 3% /month
Good high rate discharge performance
High sealed reaction efficiency : > 99%
Wide operations temperature range : 20C ~ 60C
Structure : Compact design, shorter internal connectors between cells, thus low internal resistance
Plate : Pasted flat type, with patent formula of AM
Terminal: Two or more types terminals are convenient for selection
Separator : using improved AGM separator, makes lower resistance, higher assembling pressure to increase cycle life.
Battery case: made of high strength ABS (UL94-HB) and UL94-V0 is optional
Terminal sealing : double sealing techniques (mechanical + epoxy glue)
Applications
Small UPS
Emergency Light
Security System
Toys
Medical
Compliant Standards
GB/T 19639 -2005
JIS C8702-2006
IEC 61056-2002
Passed ISO9001, ISO14001, OHSAS18001, UL, CE and TLC Certificate
SPECS | 12V5.0AH | 12V7.0AH | 12V9.0AH | 12V12AH | 12V18AH |
Cells Per Unit | 6 | ||||
Voltage Per Unit | 12 | ||||
Capacity | 5.0Ah@20hr-rate to 1.75V per cell @25 C | .0Ah@20hr-rate to 1.75V per cell @25 C | 9.0Ah@20hr-rate to 1.75V per cell @25 C | 12Ah@20hr-rate to 1.75V per cell @25 C | 18Ah@20hr-rate to 1.75V per cell @25 C |
Weight | Approx. 1.6 Kg(Tolerance±4%) | Approx. 2.04 Kg(Tolerance±2%) | Approx. 2.55 Kg(Tolerance±4%) | Approx. 3.6 Kg(Tolerance±4%) | Approx. 5.2 Kg(Tolerance±4%) |
Max. Discharge Current | 50 A (5 sec) | 70 A (5 sec) | 90 A (5 sec) | 120 A (5 sec) | 180 A (5 sec) |
Internal Resistance | Approx. 35 mΩ | Approx. 30 mΩ | Approx. 18 mΩ | Approx. 16.5 mΩ | Approx. 14 mΩ |
Operating Temperature Range | Discharge: -20 C~60 C | ||||
Charge: 0 C~50 C | |||||
Storage: -20 C~60 C | |||||
Normal Operating Temperature Range | 25 C±5 C | ||||
Float charging Voltage | 13.7 to 13.9 VDC/unit Average at 25 C | ||||
Recommended Maximum Charging Current | 1.5A | 2.1A | 2.7 | 3.6A | 5.4A |
Equalization and Cycle Service | 14.2 to 14.4VDC/unit Average at 25 C | ||||
Self Discharge | Batteries can be stored for more than 6 months at 25 C. Self-discharge ratio less than 3% per month at 25 C. Please charge batteries before using. | ||||
Terminal | Faston Tab 187(F1)/Faston tab 250(F2) | ||||
Container Material |
A.B.S. (UL94-HB), Flammability resistance of UL94-V1 can be available upon request. |