Alarm notification
Customers are notified in real-time via phone or e-mail as critical events occur, allowing them to reduce mean time to recovery, improve efficiency and maximize uptime.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Automatic Voltage Regulation (AVR)
Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Audible alarms
Provides notification of changing utility power and UPS power conditions
LED status display
Quickly understand unit and power status with visual indicators.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Netherlands Antilles , Bangladesh , Bolivia , Chile , Indonesia , Cambodia , Myanmar , Malaysia , Nepal , Peru , Philippines , Paraguay , Singapore , Thailand , Uruguay , Vietnam
Output
Output power capacity | 325Watts / 650VA |
Max Configurable Power (Watts) | 325Watts / 650VA |
Nominal Output Voltage | 230V |
Output Frequency (sync to mains) | 50/60 Hz +/-1 Hz |
Topology | Line Interactive |
Waveform type | Stepped approximation to a sinewave |
Transfer Time | 4ms typical : 6ms maximum |
Input
Nominal Input Voltage | 230V |
Input frequency | 50/60 Hz +/- 3 Hz (auto sensing) |
Input Connections | NEMA 5-15P |
Cord Length | 1.22meters |
Input voltage range for main operations | 180 - 270V |
Number of Power Cords | 1 |
Type of Input Protection Required | gL fuse |
Maximum Input Current | 5.0A |
Input Power Factor at Full Load | 0.5 |
Batteries & Runtime
Battery type | Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof | |
Included Battery Modules | 1 | |
Typical recharge time | 4hour(s) | |
Replacement Battery | APCRBC110 | |
Expected Battery Life (years) | 2 - 4 | |
Runtime | View Runtime Manual Table | |
Efficiency | View Efficiency Graph |
Communications & Management
Control panel | LED status display with On Line : On Battery |
Audible Alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Surge Protection and Filtering
Surge energy rating | 160Joules |
Filtering | -- |
Physical
Maximum Height | 141mm , 14.1CM |
Maximum Width | 101mm , 10.1CM |
Maximum Depth | 300mm , 30.0CM |
Net Weight | 4.33KG |
Shipping weight | 4.58KG |
Shipping Height | 223mm , 22.3CM |
Shipping Width | 143mm , 14.3CM |
Shipping Depth | 347mm , 34.7CM |
Color | Black |
Master Carton Units | 4.0 |
Master Carton Weight | 18.5 |
# of Layers per Pallet | 4.0 |
# of Units per Layer per Pallet | 20.0 |
Pallet Weight | 892.87lbs. |
Units per Pallet | 80.0 |
SCC Codes | 1073130431818 4 |
Environmental
Operating Temperature | 0 - 40 °C |
Operating Relative Humidity | 0 - 95 % |
Operating Elevation | 0-1968.3meters |
Storage Temperature | -20 - 50 °C |
Storage Relative Humidity | 0 - 95 % |
Storage Elevation | 0-14763.6meters |
Audible noise at 1 meter from surface of unit | 40.0dBA |
Conformance
Equipment protection policy | No EPP for ASEAN |
Sustainable Offer Status
RoHS | Compliant |
REACH | REACH: Contains No SVHCs |