INVERTER INV 2KVA – 3.5KVA is Pure sine wave output inverter which are specially used for house appliance such as TV, refrigerator, fan, air conditioner etc, and also it can be used as UPS for computers. That means It can supply power to various loads such as resitive load, inductive load, motors and rectifier load. It is equipped with programmable big current, 3 stages battery charger (10-70Amp adjustable charger) to run 10hrs longer backup time.
Characteristics
Very high load cold start by the UPS
Fast Changeover Time for smooth Switchover of Computer
Surgace Mounted Technology for Reliable and Compact Design
Free Pre-Loaded Battery Management Software
Battery Charging at as low as 120V Mains Voltage
Miniature Circuit Breaker instead of Fuse to protect load and equipment
INPUT | RATING | 2KVA/24V | 2.5KVA/36 & 48V | 3.5KVA/48V | |||
Regulated UPS Mode | |||||||
Undervoltage | 175-185V | ||||||
Undervoltage Restoration | 180-190V | ||||||
Overvoltage | 255-265V | ||||||
Undervoltage Restoration | 250-260V | ||||||
Unregulated UPS Mode | |||||||
Undervoltage | 90-110V | ||||||
Undervoltage Restoration | 105-125V | ||||||
Overvoltage | 275-295V | ||||||
Overvoltage Restoration | 260-280V | ||||||
OUTPUT | Maximum Power | 2000VA | 2500VA | 3500VA | |||
Voltage(UPS Mode) | 230 V NOMINAL | ||||||
Voltage(Mains Mode) | Same as main input | ||||||
Frequency(UPS mode) | 50 +2% Hz | ||||||
Frequency(Main mode) | Same as input(45-55Hz.) | ||||||
Overload | >110% | ||||||
Transfer Time(typical a.s) | 10msec | ||||||
Actual Wattage | 1360W + 40W | 1675W + 50W | 2350W + 50W | ||||
BATTERY | Type | 120-240AH lead Acid | |||||
Number | 2 | 3/4 | 4 | ||||
Typical Recharge Time | 10-12 Hrs | ||||||
Protection | Low Battery,Reverse Polarity | ||||||
Charging Current | 13A +1A | 17A +1A | 21A +1A | ||||
DISPLAY | UPS ON | On | |||||
Battery Low | Lo | ||||||
Mains ON | AC | ||||||
e-charge | Cx | ||||||
Battery Charged | 99% | ||||||
Overload | |||||||
No load Shutdown | nL | ||||||
Overtemperature | th | ||||||
Short circuit | OL (Blinking) | ||||||
MCB trip | bt | ||||||
ALARMS | UPS On | 5 Beep every two seconds | |||||
Low Battery Pre-alarm | Beep every 10 seconds | ||||||
Low Battery | Continous Beep for 10 seconds | ||||||
Overload | Continous Beep for 10 seconds | ||||||
No load Shutdown | Continous Beep for 10 seconds | ||||||
Short circuit | Continous Beep for 10 seconds | ||||||
ENVIRONMENTAL | Operating temperature | 0-40 C(32-104F) | |||||
Storage temperature | 0-40 C(32-104F) | ||||||
Humidity | 0-95% RH non-condensing |