INVERTER INV 750VA – 1.5KVA is Pure sine wave output inverter which are specially used for house appliance such as TV, refrigerator, fan, air conditioner etc, and also it can be used as UPS for computers. That means It can supply power to various loads such as resitive load, inductive load, motors and rectifier load. It is equipped with programmable big current, 3 stages battery charger (10-70Amp adjustable charger) to run 10hrs longer backup time.
Characteristics
Reliable, Durable and Economical Power for Grid and Mobile Applications
Very high load cold start by the UPS
Fast Changeover Time for smooth Switchover of Computer
Intelligent Thermal Management
Surface Mounted Technology for Reliable and Compact Design
Battery Charging at as low as 120V Mains Voltage
e-Charge Technology for faster charging and longer battery life
Long Back-up Time, Upto 8.0 hrs on a single PC load with 12V 150AH Battery
Free Pre-Loaded Battery Management Software
Miniature Circuit Breaker instead of Fuse to protect load and equipments
INPUT | RATING | 850VA/12V | 1100VA/12V | 1500VA/24V |
Regulated UPS Mode | ||||
Undervoltage | 175-185V | |||
Undervoltage Restoration | 180-190V | |||
Overvoltage | 255-265V | |||
Undervoltage Restoration | 250-260V | |||
Unregulated UPS Mode | ||||
Undervoltage | 90-110V | |||
Undervoltage Restoration | 105-125V | |||
Overvoltage | 275-295V | |||
Undervoltage Restoration | 260-280V | |||
OUTPUT | Maximum Power | 850VA | 1100VA | 1500VA |
Voltage(UPS Mode) | 230 V NOMINAL | |||
Voltage(Mains Mode) | Same as main input | |||
Frequency(UPS mode) | 50 +2% Hz | |||
Frequency(Main mode) | Same as input(45-55Hz.) | |||
Overload | >110% | |||
Transfer Time(typical a.s) | 10msec | |||
Actual Wattage | 560W +25W | 680W +25W | 1025W +40W | |
BATTERY | Type | 120-150AH lead Acid | 120-240Ah Lead Acid | |
Number | 1 | 1 | 2 | |
Typical Recharge Time | 10-12 Hrs | |||
Protection | Low Battery,Reverse Polarity | |||
Charging Current | 12A +1A | 22A +1A | 14A +1A | |
DISPLAY | Swicth On | White | Green | - |
UPS ON | UPS ON LED RED when running on battery mode | UPS ON LED WHITE when running on battery mode On | ||
Low Battery Pre-alarm | UPS ON & LOW BATTERY LED | - | ||
Battery Low | BATTERY LOW RED on battery low cutoff | BATTERY LOW WHITE on battery low cutoff | Lo | |
Mains ON | MAINS ON RED GLOWING | MAINS ON WHITE GLOWING | AC | |
Battery Charged | - | - | 99% | |
e-charge | RED(Along with Mains LED) | WHITE(Along with Mains LED) | CH | |
Overload | OVEROAD RED LED GLOWING | OVEROAD WHITE LED GLOWING | OL(steady) | |
No load Shutdown | - | - | NL | |
Overtemperature | - | - | BL | |
Short circuit | OVEROAD RED LED GLOWING | OVEROAD WHITE LED GLOWING | OL(Blinking) | |
MCB trip | e-charge LED BLINKING | BL | ||
ALARMS | UPS On | 5 Beep every two seconds | ||
Low Battery Pre-alarm | Beep every 30 seconds | Beep every 10 seconds | ||
Low Battery | Continous Beep for 10 seconds | |||
Overload | Continous Beep for 10 seconds | |||
No load Shutdown | Continous Beep for 10 seconds | |||
Short circuit | Continous Beep for 10 seconds | |||
ENVIRONMENTAL | Operating temperature | 0-40 C(32-104F) | ||
Storage temperature | 0-40 C(32-104F) | |||
Humidity | 0-95% RH non-condensing |