Our Full Sine wave Smart UPS has DSP Digital Control technology which boost and buck AVR for voltage Stabilization and auto restart when mains power is restored.
Characteristics
CAPACTITY | 500 VA / 300 W | 1000 VA / 800 W | 1500 VA / 1200 W | 2000 VA / 1600 W | 3000 VA / 2400 W | |||
DC INPUT | ||||||||
Rated voltage | 12 V | 24 V | 36 V (S) 48V (H) | 48 V | ||||
DC Input range (default) | 10 ~ 15 V | 20 ~ 30 V | 30 ~ 45 V(S) 40~60V(H) | 40~60 V | ||||
AC INPUT | ||||||||
AC Input range (bypass mode) | 0~121 V/ 132 V /138V / 144Vac for 100 V / 110 V / 115V / 120 Vac +- 10 Vac | |||||||
0~242 V/ 246 V/ 276 V/ 288 Vac for 200V / 220V / 230V / 240 Vac +-10 Vac | ||||||||
AC Input range (mains mode) | 100V: 70~130Vac 110V:80~140Vac 115V:85~145Vac 120V:90~150Vac | |||||||
200V:145~260Vac 220V:165~280Vac 230V:175~290Vac 240V:185~300Vac | ||||||||
Frequency Input Range | 50HZ / 60Hz (auto-sense), 50Hz / 60 Hz + 5% - 15% | |||||||
Generator Connection | Avaliable (generator input power is settable) | |||||||
OUTPUT | ||||||||
Inverter Output range | 100V / 110V /115V / 120V / 200V / 230V/ 240V + 5% (settable) | |||||||
AC Output Range (bypass mode) | 0~121 V/ 132 V /138V / 144Vac for 100 V / 110 V / 115V / 120 Vac +- 10 Vac | |||||||
0~242 V/ 246 V/ 276 V/ 288 Vac for 200V / 220V / 230V / 240 Vac +-10 Vac | ||||||||
AC Output Range (mains mode) | 100V: 90~110Vac 110V:99~121Vac 115V:103~126Vac 120V:108~132Vac | |||||||
200V:166~226Vac 220V:188~245Vac 230V:199~254Vac 240V:210~264Vac | ||||||||
Output Frequency | 50 /60Hz + 0.3 Hz (settable) | |||||||
Waveform | Pure Sine Wave | |||||||
Inverter Efficiency | Max. 75% | Max. 80% | Max. 85% | |||||
Energy Saving Mode | Settable (<3% load), enter in 80 s | |||||||
No-load shutdown | Settable (<3% load), shut down in 80 s | |||||||
Transfer Time | < 10ms | |||||||
THDV ( Resistive Load) | < 5% | |||||||
Portections | Overload, Short Circuit (inverter), Battery low Voltage, Battery overcharge, Overtemperature | |||||||
Overload Time (mains mode) | 120 s for 110 %, 60s for 125%, 10s for 150% (transfer to bypasss mode) | |||||||
Overload Time (inverter mode) | 60 s for 110%, 10s for 125%, 5s for 150% (Shut down directly) | |||||||
Mute | Automatic mute in 60s or by normal | |||||||
BATTERIES | ||||||||
Battery Capacity (H:external expansion) | 12 V x 1 | 12 V/7 Ah x 2 | 12 V/9 Ah x 2 | 12 V/9 Ah x 3 (H: 12Vx4) | 12 V/9 Ah x 4 | |||
Charging Current | Standard Model (S):1 A (default) | |||||||
Long Time Model (H): 10A (default); <10A, set step 1A; > 10A, set step 5A | ||||||||
Max. 10A(H) | Max. 15A(H) | / | Max. 20A(H) | Max. 25A(H) | ||||
Equalizing Charge Voltage | Single battery 14.1 Vdc (default), 13.6~15 Vdc adjustable | |||||||
Floating Charge Voltage | Single battery 13.5 Vdc (default), 13.2~14.6 Vdc adjustable | |||||||
Low Voltage Alarm Point | Single battery 10.8 Vdc (default), 9.6~13 Vdc adjustable | |||||||
Low Voltage Shutdown Point | Single battery 10.2 Vdc (default), 9.6~11.5 Vdc adjustable | |||||||
OTHERS | ||||||||
Operating Temperature | 5C ~ 40C | |||||||
Operating Humidity | Relative Humidity < 93% | |||||||
Noise Level | < 50dB (1m) | |||||||
Tower | Dimensions (WxDxH)(mm) | 345 x 215 x 144 (S/H) | 410 x 215 x 144 (S) | 467 x 335.5 x 190 (S/H) | ||||
Packaged Dimensions (WxDxH)(mm) | 427 x 316 x 236 (S/H) | 492 x 316 x 236 (S) | 592 x 462 x 320 (S/H) | |||||
Net Weight (kg) | 7.0 (H) | 12.2(S) 11.6(H) | 18.5 (S) 17.8(H) | 28.1 (S) 28.0(H) | ||||
Gross Weight (kg) | 8.0 (H) | 13.2(S) 12.6(H) | 19.8 (S) 18.8 (H) | 30.2 (s) 30.0(H) | ||||
Rack Mount | Dimensions (WxDxH)(mm) | / | 440 x 338 x 88 (S) | 440 x 410 x 132 (S) | ||||
Packaged Dimensions (WxDxH)(mm) | / | 611 x 448 x 208 (S) | 611 x 505 x 235 (S) | |||||
Net Weight (kg) | / | 14.6 (S) | 17.2 (S) | 21.3 (S) | 26.7 (S) | |||
Gross Weight (kg) | / | 16.8 (S) | 20.4 (S) | 24.5 (S) | 30.5 (S) |